.jpg)
Sundez EVI Monobloc Low Ambient Temperature Air to Water Heat Pump
Sundez EVI low ambient temperature air to water heat pump is designed for house heating as well as sanitary hot water in cold area, including North Europe and East Europe. This is one of the best air source heat pumps for cold area currently, with reliable operation at -25DegC ambient temperature, and the COP at -15DegC ambient temperature is up to 2.2.
Features:
1. Designed for central heating for houses in cold area including North Europe and East Europe.
2. Can work stably at -25DegC ambient, and the COP at -15DegC ambient is up to 2.2.
3. Can work with indoor thermostat.
4. Can work with auxiliary heater.
5. Using electronic expansion valve, achieving accurate, stable and high efficiency throttling.
6. Monobloc design with reliable anti-frozen protection from the controller.
7. Low noise design. The fan is axial fan with big air volume, but low rotate speed and low noise.
8. The cabinets are made in galvanized steel with powder coating.
Model
|
|
SDAW-075BEVIM
|
SDAW-125BSEVIM
|
SDAW-250BSEVIM
|
Power Supply
|
V/ph/Hz
|
220~240/1/50
|
380~400/3/50
|
380~400/3/50
|
Heating Capacity
|
KWA7/W35
|
10.0
|
15.0
|
34
|
Heating Power Input
|
KWA7/W35
|
2.7
|
3.5
|
7.4
|
Heating Capacity
|
KWA7/W45
|
9.8
|
14.6
|
33
|
Heating Power Input
|
KWA7/W45
|
2.7
|
3.5
|
8.3
|
Heating Capacity
|
KWA-15/W35
|
6.9
|
10.1
|
22
|
Heating Power Input
|
KWA-15/W35
|
3.2
|
4.6
|
8.76
|
Heating Capacity
|
KWA-15/W45
|
7.1
|
10.3
|
23
|
Heating Power Input
|
KWA-15/W45
|
3.3
|
4.7
|
9.58
|
Heating Start Current
|
A
|
68
|
41
|
41
|
Heating Running Current
|
A
|
13.4
|
7.7
|
15.7
|
Water Flow Volume
|
Ton/hour
|
1.7
|
2.7
|
5.6
|
Refrigerant
|
|
R417A
|
R417A
|
R410A
|
Net Dimension(D*W*H)
|
mm
|
930*405*960
|
1120*430*1250
|
1510*570*1600
|
Net Weight
|
kg
|
98
|
135
|
305
|
Noise Level
|
dBA
|
55
|
55
|
58
|
Workable ambient temperature
|
℃
|
-25~35
|
-25~35
|
-25~35
|
|